DIGITAL PORTABLE 4.0/8.0 kW DRAGON LW SYSTEM
DRAGON LW PORTABLE SYSTEM - WITH TOSHIBA FDX3543RP FLAT PANEL
It is completely integrated and combines the high-frequency x-ray generator’s functions with the DR system’s software, creating an efficient solution for portable x-ray requirements.
CONSISTING OF:
- Generator SPSLW-AL
- Portable Stand Dragon X Digital
- ImagePlus Software
- Toshiba FDX3543RP Flat Panel Detector
GENERATOR
- Console control integrated on the system with digital readout of kVp, mAs large/small focus selection, collimator light indicator, and audible x-ray exposure signal
- Auto diagnostic system with error codes for easy maintenance
- kV selection from 40 to 125 (in 1 kVp step)
- kVp Accuracy ± 3% +1kV
- mA Range from 5 to 100 mA: 5, 6.4, 8, 10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80, 100
- mAs, Automatic selection of the highest mA and shortest time based on tube limits.
- Range of mAs, from 0.1 – 250 mAs (in 25% steps)
- mAs Accuracy ± 5% + 0.1 mAs
- Range of exposure times, from 0.001 to 10 seconds, automatic selection of the mAs. It can be shown in the display by pressing simultaneously any bottom, for focus or mAs selection. (in 25% steps)
- ms Accuracy ± 2% + 0.1 ms
- Manual collimator centering light indicator. SID measuring tape
- Power cord 19.7 ft (6 m.)
- X-Ray exposure cable 9.8 ft (3 m.)
DRAGON LW PORTABLE SYSTEM - WITH TOSHIBA FDX3543RP FLAT PANEL
It is completely integrated and combines the high-frequency x-ray generator’s functions with the DR system’s software, creating an efficient solution for portable x-ray requirements.
CONSISTING OF:
- Generator SPSLW-AL
- Portable Stand Dragon X Digital
- ImagePlus Software
- Toshiba FDX3543RP Flat Panel Detector
GENERATOR
- Console control integrated on the system with digital readout of kVp, mAs large/small focus selection, collimator light indicator, and audible x-ray exposure signal
- Auto diagnostic system with error codes for easy maintenance
- kV selection from 40 to 125 (in 1 kVp step)
- kVp Accuracy ± 3% +1kV
- mA Range from 5 to 100 mA: 5, 6.4, 8, 10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80, 100
- mAs, Automatic selection of the highest mA and shortest time based on tube limits.
- Range of mAs, from 0.1 – 250 mAs (in 25% steps)
- mAs Accuracy ± 5% + 0.1 mAs
- Range of exposure times, from 0.001 to 10 seconds, automatic selection of the mAs. It can be shown in the display by pressing simultaneously any bottom, for focus or mAs selection. (in 25% steps)
- ms Accuracy ± 2% + 0.1 ms
- Manual collimator centering light indicator. SID measuring tape
- Power cord 19.7 ft (6 m.)
- X-Ray exposure cable 9.8 ft (3 m.)